Skip to main content
. 2019 Jan 16;2019(1):CD011204. doi: 10.1002/14651858.CD011204.pub2

8. Methods for measuring [Na+] in included studies.

Study ID Serum [Na+] Dialysate [Na+]
Akdag 2015 Not reported Not reported
Beduschi 2013 Reflectance spectrophotometrya Dialysate conductivitya
Boquin 1977 Not reported Not reported
Chambers 2002 Not reported Not reported
Daugirdas 1985 Flame photometryb Flame photometryb
Henrich 1982 Flame photometry Flame photometry
Liu 2016 Ion selective electrode Dialysate conductivity
MATCH‐NA 2015 Ion selective electrodec Dialysate conductivityc
Ogden 1978 Flame photometry Dialysate conductivity
Suckling 2013 Ion selective electrode Ion selective electrode
Van Kuijk 1996 Ion selective electrode Dialysate conductivity
Quereda 1988 Not reported Not reported

aPersonal communication Pasqual Barretti 18 July 2018

bPersonal communication John T Daugirdas 17 July 2018

cPersonal communication Jula Inrig 17 July 2018