Table 1.

Tolerance to heavy metals (MIC (mg L−1)), time for total reduction of 100 mg L−1 Cr (VI) and PGP characteristics of bacterial isolates.

MIC (mg L−1)
Tot. red. of 100 mg L−1 Cr(VI) PGP traits
Strain Cr(VI) Zn Cu Ni Pb Co Time (h) PSI IAA (μg mL−1) Siderophores
NF1 600 500 400 500 1000 400 60 38.89 +
NF2 800 1500 400 500 1500 400 48 2.66 88.53 +
NF3 400 500 300 500 1500 500 60 56.83
NF4 500 500 400 500 1500 400 72 32.26
NF5 900 1000 400 500 1500 400 96 96.14 +
NF6 900 1500 200 500 1500 1000 96 2.60 40.61
NF7 400 500 300 500 1500 400 120 43.56 +
NF8 600 1500 400 300 1500 400 96 12.51 +
NF9 600 2000 400 500 1500 500 96 33.24 +
NF10 700 1500 400 1000 1500 500 96 2.50 48.97
NF11 400 1000 200 500 1500 500 120 74.26
NF12 500 1500 400 500 1500 500 96 65.68
NF13 500 1500 400 300 1500 1000 96 2.20 41.35
NF14 600 500 300 500 1500 1000 96 2.45 39.63
NF15 500 2000 300 500 1500 1000 72 3.33 36.68
NF16 500 1000 300 500 1500 500 96 2.36 37.91
NF17 500 1000 300 300 1500 500 96 43.07 +
NF18 600 1000 300 300 2000 500 96 58.30 +
NF19 700 500 400 500 1500 500 60 74.20 +
NF20 700 1500 400 400 1500 500 72 2.50 43.32
NF21 600 1500 300 400 1500 400 60 2.60 51.92
NF22 400 1000 300 500 1500 500 96 2.66 43.56
NF23 400 1000 400 1000 1500 500 120 74.28
NF24 600 2000 300 400 1500 500 60 2.50 47.00
NF25 500 1000 500 100 1500 500 144 53.14 +
NF26 500 2000 300 500 1500 500 48 2.50 47.00
NF27 700 400 100 500 1500 500 120 2.30 42.09