Skip to main content
. 2019 Jan 31;19(Suppl 1):22. doi: 10.1186/s12911-019-0736-9

Table 4.

– Comparison of performance of different systems reported on the same i2b2–2010 corpus

Publications Models Precision (%) Recall (%) F-measure (%)
Rink et al. [33] SVM 67.44 57.85 59.31
Sahu te al. [19] Multi-CNN-Max 55.73 50.08 49.42
Sahu and Anand [34] LSTM-ATT 65.23 56.77 60.04
Wang et al. [35] RCNN 50.07 45.34 46.47
Raj et al. [20] CRNN 67.91 61.98 64.38
*Luo et al. [21] Seg-CNN 74.20
Our model 75.69 73.03 74.34

*Luo et al. used the original dataset from the challenge (871 documents in total)