Skip to main content
. 2019 Jan 4;9(1):8. doi: 10.3390/membranes9010008

Table 5.

DMS model fugacity-based parameter sets used in the calculation of mixed-gas sorption of CH4 in PIM-1 reported in Figure 8.

T kD,CH4 CH,CH4 bCH4 SEEpure SEE¯ mix
(°C) (cmSTP3cmpol3bar) (cmSTP3cmpol3) (bar1) (cmSTP3cmpol3bar) (cmSTP3cmpol3bar)
Set 1 25 0.945 65.08 0.186 0.999 3.98
35 0.119 101.81 0.074 0.891 1.15
50 0.125 82.00 0.070 0.797 1.35
Set 2 25 0.316 96.99 0.102 0.996 11.16
35 0.869 59.26 0.152 0.899 4.95
50 0.767 45.62 0.155 0.792 3.67