Table 1.

Interferents to electrochemical detection of nitric oxide.

Interferent Ea(mV) Concentration (nM) Media Reference
NO2 800-1200 >20,000 Blood [25]
AA 100-300 43,000 Serum [26]
CO 200-500 500-1500 Kidney tissue [27]