Table 1.

Best-fit values of the material parameters used to fit the biaxial mechanical data and thus to compute biaxial stress, material stiffness, and stored energy for the Ltbp3−/− and Fbn1mgR/mgR:Ltbp3−/− vessels. Values of the parameters for WT, Fbn1mgR/mgR, and aneurysmal Fbn1mgR/mgR (TAA) aortas are reproduced from (Bellini et al. 2016) for convenience.

Elastic Fibers Axial Collagen Circumferential Collagen + SMC Symmetric Diagonal Collagen Error
c (kPa) c11 (kPa) c21 c12 (kPa) c22 c13,4 (kPa) c13,4 α0 (deg) RMSE

ATA
Ltbp3−/− 39.856 19.266 0.080 0.005 1.182 5.813 0.363 47 0.059
Fbn1mgR/mgR:Ltbp3−/− 45.822 28.206 0.312 0.035 1.194 5.737 0.871 41 0.049
WT 43.993 14.978 0.028 7.590 0.234 6.476 0.426 44 0.048
Fbn1mgR/mgR 23.102 12.988 0.230 0.009 2.389 7.478 0.747 47 0.068
Fbn1mgR/mgR TAA 21.687 11.139 0.005 8.44E−05 8.289 11.138 1.555 50 0.092

DTA
Ltbp3−/− 36.546 10.666 0.451 7.380 0.236 0.073 2.212 31 0.070
Fbn1mgR/mgR:Ltbp3−/− 27.564 10.662 0.929 3.929 0.197 0.033 3.144 29 0.082
WT 31.944 13.496 0.163 11.213 0.146 0.097 1.816 27 0.054
Fbn1mgR/mgR 29.040 1.293 1.778 1.139 0.577 0.338 2.384 29 0.084