Evaluation of the Xpert CT/NG and OSOM TV against the Anyplex II STI-7 Detection and FTD STD9 assays (n=247)

POC assay Anyplex II STI-7 Detection +/- FTD STD9 Accuracy with 95% CI
Positive Negative
Xpert CT Positive 37 5 Sensitivity=100% (100% to 100%)
Specificity=97.6% (95.6% to 99.7%)
PPV=88.1% (78.3% to 97.9%)
NPV=100% (100% to 100%)
Negative 0 205
Xpert NG Positive 12 0 Sensitivity=100% (100% to 100%)
Specificity=100% (100% to 100%)
PPV=100% (100% to 100%)
NPV=100% (100% to 100%)
Negative 0 235
OSOM TV Positive 6 0 Sensitivity=75.0% (45.0% to 100%)
Specificity=100% (100% to 100%)
PPV=100% (100% to 100%)
NPV=99.2% (98.0% to 100%)
Negative 2 239