Table 1.

Summary of EPI brain studies. All brain data were acquired with 1.5 × 1.5 cm2 in-plane resolution using a constant 20° pyruvate/30° lactate/30° bicarbonate flip angle scheme and an integrated birdcage and 32 channel head coil. Time-to-peak (TTP) signal is referenced from the start of acquisition, and the reported polarization is referenced to the start of dissolution. The error in center frequency calibration (Δf) was measured with non-localized spectroscopy following dynamic imaging.

Δf (Hz) 13C
Polarization
Time to
injection
Pyruvate Lactate Bicarbonate
Peak
SNR
TTP Peak
SNR
TTP Peak
SNR
TTP
Study #1 +3.7 41.3% 54s 447 9s 30 12s 6 15s
Study #2 +3.7 41.9% 60s 396 3s 28 6s 7 9s
Study #3 +6.1 33.1% 53s 402 9s 16 9s 8 15s