Skip to main content
. 2019 Feb 12;10(2):136. doi: 10.1038/s41419-019-1355-1

Table 1.

Radiation biologic parameters of ESCC cells in different groups

Cell lines Group D0 (Gy) Dq (Gy) N SF2 (%)
TE-1 Control 3.34 ± 0.24 1.88 ± 0.17 1.76 ± 0.41 72.01 ± 2.50
siHMGB1 2.47 ± 0.31a,* 1.83 ± 0.11a,* 2.10 ± 0.38a, * 69.08 ± 3.70 a,*
siHMGB1 + EBSS 3.55 ± 0.26b,* 2.58 ± 0.21b,* 2.07 ± 0.35b,* 80.11 ± 1.70b,*
EBSS 3.64 ± 0.27 2.81 ± 0.18 2.16 ± 0.37 83.10 ± 1.24
Eca-109 Control 3.18 ± 0.19 1.47 ± 0.31 1.59 ± 0.04 70.32 ± 3.30
siHMGB1 2.48 ± 0.32a,* 1.44 ± 0.19a,* 1.79 ± 0.22a, * 65.71 ± 4.50a,*
siHMGB1 + EBSS 3.88 ± 0.41b,* 2.00 ± 0.23b, * 1.66 ± 0.33b, * 75.11 ± 2.90b,*
EBSS 3.98 ± 0.26 2.38 ± 0.21 1.82 ± 0.39 78.14 ± 1.40

Note: Radiobiological parameters (D0, Dq, N and SF2) were calculated from the single-hit multitarget model (SF = 1−(1−e^ [−kD]) ^N) using GraphPad Prism 7.0

D0: final slope; Dq: quasi-threshold dose; N: extrapolation number; SF2: survival fraction of 2 Gy

*P < 0.05, t test

asiHMGB1 vs. control

bsiHMGB1 + EBSS vs. siHMGB1