Table 5. The comparison between video-assisted and telephone DA-CPR for different components of CPR quality in 6 studies.

Correct chest compression depth Correct chest compression rate Full chest recoil Minimal interrupted chest compression Correct hand position Shorter time to start chest compression Ventilation
Number of studies showing video-assisted DA-CPR is superior 217,20 417,20,39,50 0 139 317,39,50 150 228,39
Number of studies showing telephone DA-CPR is superior 0 0 0 220,50 0 320,28,39 117
Number of studies showing both methods were the same 339,46,50 146 146 146 220,46 217,46 146
Number of studies without measurement 128 128 517,20,28,39,50 217,28 128 0 120