Skip to main content
. 2019 Feb 19;6(1):014005. doi: 10.1117/1.JMI.6.1.014005

Table 1.

Comparison of different number of filters.

  MSE (SD) Number of parameters Inference time (s)
F1=F2=F3=32 1094.52 (49.46) 60.6 K 0.72
F1=F2=F3=64 918.07 (41.70) 213.7 K 1.34
F1=F2=F3=96 909.84 (38.68) 513.5 K 2.58