Skip to main content
. 2019 Jan 18;141(3):0310051–03100511. doi: 10.1115/1.4042184

Fig. 4.

Fig. 4

Comparison of results for models with asymmetric stenoses: (a) computed FFR distribution from 3D CFD for a 73% asymmetric stenosis, (b) pressure drop across stenosis for model 3 (0D) and full 3D CFD simulation for the 73% asymmetric stenosis, (c) computed FFR distribution from 3D CFD for a 90% asymmetric stenosis, and (d) pressure drop across stenosis between model 3 (0D) and full 3D CFD simulation for the 90% asymmetric stenosis