Table 1.
Ambulatory assessment specification | References | ||
---|---|---|---|
Device | Customized device (e.g., Actigraph, Tracmor, IDEEA, etc.) |
Troped et al., 2008; De Vries et al., 2011; Ruch et al., 2011; Skotte et al., 2014; Fergus et al., 2015, Bonomi et al., 2009; Godfrey et al., 2011; Gyllensten and Bonomi, 2011; Reiss and Stricker, 2011; Kwak and Lee, 2012; Nguyen et al., 2013; van Hees et al., 2013; Adaskevicius, 2014; Barshan and Yuksek, 2014; el Achkar et al., 2016 |
|
Smartphone | Bisio et al., 2012; Bayat et al., 2014; Shoaib et al., 2014; Spinsante et al., 2016 | ||
Sensor type | Accelerometer Accelerometer + Additional sensor (e.g., heart rate, GPS, pressure sensor, imaging sensor, barometer, etc.) |
1D | De Vries et al., 2011, Troped et al., 2008; Ruch et al., 2011; Nguyen et al., 2013; Fergus et al., 2015; el Achkar et al., 2016 |
2D | Nguyen et al., 2013; el Achkar et al., 2016 | ||
3D | Bonomi et al., 2009; Godfrey et al., 2011; Gyllensten and Bonomi, 2011; Bisio et al., 2012; Bayat et al., 2014; Spinsante et al., 2016, Kwak and Lee, 2012; van Hees et al., 2013; Adaskevicius, 2014; Shoaib et al., 2014; Skotte et al., 2014 |
||
IMU (3D accelerometer + 3D gyroscope + 3D magnetometer) IMU+ Additional sensor |
Barshan and Yuksek, 2014, Reiss and Stricker, 2011; el Achkar et al., 2016 |
||
Number of sensors | 1 Accelerometer 1 Accelerometer + Additional Sensor |
Bonomi et al., 2009; Godfrey et al., 2011; Bisio et al., 2012; Bayat et al., 2014; Spinsante et al., 2016, Troped et al., 2008; Kwak and Lee, 2012; Adaskevicius, 2014; Fergus et al., 2015 |
|
>1 Accelerometer >1 Accelerometer + Additional Sensor |
De Vries et al., 2011, Reiss and Stricker, 2011; Ruch et al., 2011; Nguyen et al., 2013; van Hees et al., 2013; Barshan and Yuksek, 2014; Shoaib et al., 2014; Skotte et al., 2014; el Achkar et al., 2016 |
||
Sampling rate | Counts/steps | Troped et al., 2008; De Vries et al., 2011; Godfrey et al., 2011; Ruch et al., 2011; Nguyen et al., 2013; Fergus et al., 2015; el Achkar et al., 2016 | |
Medium (20–50 Hz) | Bonomi et al., 2009; Gyllensten and Bonomi, 2011; Adaskevicius, 2014; Barshan and Yuksek, 2014; Shoaib et al., 2014 Skotte et al., 2014 Garcia-Ceja and Brena, 2016 Spinsante et al., 2016 | ||
High (>50 Hz) | Reiss and Stricker, 2011; van Hees et al., 2013; Bayat et al., 2014; Garcia-Ceja and Brena, 2016 | ||
Sensor placement | One part of body | C | Makikawa and Murakami, 1996; Troped et al., 2008; Bonomi et al., 2009; Fergus et al., 2015 |
U | Godfrey et al., 2011; Kwak and Lee, 2012; Adaskevicius, 2014 | ||
L | Bisio et al., 2012; Spinsante et al., 2016 | ||
Two parts of body | H&L | Bayat et al., 2014 | |
C&L | De Vries et al., 2011; Nguyen et al., 2013; Skotte et al., 2014; el Achkar et al., 2016 | ||
C&H | Ruch et al., 2011 | ||
Three parts of body | U&C&L | Gyllensten and Bonomi, 2011 | |
U&L&H | Reiss and Stricker, 2011; Barshan and Yuksek, 2014 | ||
C&L&H | van Hees et al., 2013; Shoaib et al., 2014 | ||
Four parts of body | C&L&H&U | Garcia-Ceja and Brena, 2016 |
D, Dimension; IMU, inertial measurement unit; Hz, Hertz; C, central part of body; U, upper part of body; L, lower part of body; H, hand.