Table 2:

Summary of experimental procedure for the four methods

Method
Number
Method Name Description
All voltages are peak to peak
1 High-Low Start block suprathreshold at 10 V or 16 V.
Decrease in 1 V decrements until twitches return.
2 High-Low-High Start block suprathreshold at 10 V or 16 V.
Decrease in 1V increments until twitches return.
Continue to decrease until 2 V below first threshold.
Increase in 1 V increments until twitches disappear
3 Binary Search a range from 0-16V starting in the middle at 8V.
Two possible next steps:
1) If complete block achieved then values above 8V eliminated and test middle of remaining range, from 4V.
2) If complete block was not achieved, then values below 8 V eliminated and test middle of remaining range, or from 12V.
Repeat steps 1 and 2 until block threshold is determined within a 1V resolution
4 Random Test block values in a randomly generated order within the below ranges (ranges based on preliminary data from animal # 1):
10 kHz: 2-9 V
20 kHz: 4-11 V
30 kHz: 5-12 V