Skip to main content
. 2019 Feb 19;9:2277. doi: 10.1038/s41598-019-39053-0

Figure 2.

Figure 2

Effect of helium implantation parameters on the SAXS signal from bubbles and gas bubble superlattices in tungsten with sample ID in parentheses: (a) Temperature (to a fluence of 1 × 1017 ions/cm2 with a flux of 6.2 × 1012 ions/cm2/s), (b) Fluence (at 500 °C with a flux of 2.7 × 1012 ions/cm2/s); (c) Flux (at 500 °C to a fluence of 1 × 1017 ions/cm2). All samples have helium bubbles and the symbol *indicates samples that have gas bubble superlattices. Samples are offset in the vertical direction for clarity. The scattering vector Q is related to characteristic length D by: Q = 2π/D.