Skip to main content
. 2019 Feb 19;9:2319. doi: 10.1038/s41598-018-37254-7

Table 3.

Potentiodynamic polarization parameters (derived from Fig. 5) for C-steel in 0.5 M HCl in the presence of 0, 20, 30, 35, 40 μmol L−1 of AEO7 corrosion inhibitor at different temperatures.

T (°C) Cinh µmol L−1 Ecorr (mV) SCE icorr (µA cm−2) βa, mV decade−1 βc, mV decade−1 Rp, Ω cm2 CR, mm year −1 θ IE %
20 Blank 496.0 624 152.8 164.8 55.2 7.24
20 478.0 194 97.2 157.9 130.1 2.25 0.68 68.91
30 460.0 130 87.8 148.6 199.9 1.5 0.80 80.40
35 458.0 71.5 68.1 123.6 266.9 0.83 0.88 88.54
40 417.0 45.5 40.1 112.6 282.5 0.52 0.92 92.70
30 Blank 499.0 1056 202.2 192.8 40.6 12.26
20 487.0 353.68 122 173.3 88.01 4.1 0.66 66.5
30 471.0 250.9 107.5 162.9 127.9 2.91 0.79 79.3
35 467.0 150.4 85.5 148.5 156.8 1.74 0.85 85.75
40 470.0 95.8 56.8 129 178.9 1.11 0.90 90.92
40 Blank 513.0 1640 249.5 328.4 37.5 19.04
20 487.0 567 211.2 272.1 91.1 6.58 0.65 65.42
30 464.0 419 183.5 250.5 122.1 4.86 0.77 77.45
35 457.0 277 149.5 225.7 141.1 3.21 0.83 83.10
40 469.0 166 93.8 143.9 148.7 1.92 0.89 89.87
50 Blank 518.0 2440 423 352 34.2 28.34
20 522.0 896 281 323.9 73.0 10.4 0.63 63.27
30 480.0 650 183.1 285.3 80.8 7.54 0.75 75.36
35 486.0 425 98.1 260.6 68.8 4.93 0.81 81.70
40 492.0 301 44.9 235.3 54.4 3.49 0.78 87.66