Skip to main content
. 2019 Feb 6;2019:8790694. doi: 10.1155/2019/8790694

Table 5.

Effect of scan parameters on computer features in −630 HU phantom nodules.

Image features Slice thickness mAs Reconstruction algorithm
5.00 vs 1.25 5.00 vs 2.50 2.50 vs 1.25 30 vs 120 Lung vs standard
Effect d Effect d Effect d Effect d Effect d
Histogram Mean < 2.85 < 2.71 < 0.28 0 0.07 > 1.11
Stddev < 0.71 0 0.25 < 0.50 > 0.72 > 1.65
Variance < 0.74 0 0.35 < 0.55 > 0.68 > 1.20
Skewness < 1.15 < 1.25 0 0.19 < 0.61 < 1.04
Kurtosis > 0.40 > 0.63 < 0.16 > 0.58 > 2.77
Energy 0 0.10 < 0.29 > 0.31 < 0.89 < 2.46
Entropy < 0.52 0 0.07 < 0.38 > 0.85 > 2.56

GLCM Contrast < 1.32 < 0.97 < 0.65 > 0.58 > 1.27
Dissimilarity < 1.21 < 0.74 < 0.56 > 0.65 > 1.67
Homogeneity > 0.69 > 0.16 > 0.40 < 0.79 < 2.81
ASM > 0.48 0 0.03 > 0.42 < 0.87 < 1.53
Energy > 0.55 0 0.08 > 0.41 < 0.87 < 1.80
Probability max > 0.34 0 0.06 0 0.26 < 0.76 < 1.21
Entropy < 0.63 0 0.20 < 0.41 > 0.75 > 1.72
Correlation > 1.20 > 0.80 > 0.65 < 0.58 < 1.21

GLRLM LRE > 0.40 0 0.08 > 0.34 < 0.79 < 2.12
GLN 0 0.13 < 0.23 > 0.31 < 0.91 < 2.23
RLN < 0.46 0 0.02 < 0.34 > 0.83 > 2.27
LGRE > 0.98 > 1.49 0 0.35 0 0.21 0 0.13
HGRE < 2.89 < 2.64 < 0.44 > 0.20 > 1.09

<  indicates p ≤ 0.05 and A is statistically smaller than B (A vs B); >  indicates p ≤ 0.05 and A is statistically larger than B (A vs B); 0 indicates A and B are not statistically significant (A vs B). Cohen's d: small ≥ 0.20; medium ≥ 0.50; large ≥ 0.80.