Skip to main content
. Author manuscript; available in PMC: 2019 Feb 20.
Published in final edited form as: Meas Sci Technol. 2016 Dec 20;28(2):025101. doi: 10.1088/1361-6501/28/2/025101

Table 2.

Summary of the surface pH changes on brass coupons and a galvanic solder coupon.

Metal Coupons Flow condition Stagnation
Ave. pH ΔpH Ave. pH ΔpH
Aged brass (80 days) 9.0 ± 0.03
max.: 9.1
min.: 9.0
0.1 9.4 ± 0.08
max.: 9.5
min.: 9.0
0.5
Aged brass (200 days) 9.0 ± 0.08
max.: 9.1
min.: 8.8
0.3 9.2 ± 0.08
max.: 9.4
min.: 9.1
0.3
Brass-lead galvanic connection (14 days) 9.1 ± 0.12
max.: 9.4
min.: 8.9
0.4 8.9 ± 0.51
max.: 10.0
min.: 7.9
2.1
*

Initial bulk pH was 9.0.