Skip to main content
. 2019 Jan 25;4(1):83–88. doi: 10.1002/lio2.226

Table 3.

Prediction Accuracy for Each Measure

Variable P‐Value Prediction Accuracy (%) Sensitivity (%) Specificity (%)
Hyoid Displacement (Hmax) (cm) <.001 69.6 60.6 72.8
Hyoid‐Larynx Approximation (HL) (cm) <.001 67.3 60.6 69.8
Pharyngoesophageal Segment Opening (PESmax) (cm) <.001 69.7 51.4 73.0
Pharyngeal Constriction Ratio (PCR) <.001 74.6 58.7 80.2
Pharyngeal Transit Time (TPT) (secs) <.001 65.9 59.7 67.9
All Variables P‐Value Prediction Accuracy (%) Sensitivity (%) Specificity (%)
COMBINED 76.5 76.5 65.1
Hyoid Displacement (Hmax) (cm) <.001
Hyoid‐Larynx Approximation (HL) (cm) <.003
Pharyngoesophageal Segment Opening (PESmax) (cm) .053
Pharyngeal Constriction Ratio (PCR) <.001
Pharyngeal Transit Time (TPT) (secs) <.001

At top, results of binary regression analyses for individual objective measures, with age and gender as categorical covariates. At bottom, results for combined measures are presented, with age and gender as categorical variables. Cutoff point was proportion of patients who aspirated.