Skip to main content
. 2018 Jul 23;24(1):51–63. doi: 10.1007/s11367-018-1504-2

Table 4.

Ranges to test sensitivity of results to design life and factors relating to the installation location

Parameter Original value Range tested
Annual energy output, represented by capacity factor 45% 25–55%
Distance of installation location from fabrication yard 320 km 20–320 km
Distance to steel fabrication yard from Pelamis factory 420 km 210–630 km
Design life 20 years 10–30 years