Skip to main content
. 2018 Nov 9;126(1):183–192. doi: 10.1152/japplphysiol.00464.2018

Table 4.

Average %VV and median Hscore values over sessions 1 and 2 generated from hyperpolarized 3He and 129Xe images for the three volunteers scanned with both gases

3He V2 129Xe V2 3He V3 129Xe V3 3He V6 129Xe V6
Acquisition, %VV
    RV 98.68 96.26 97.03 NA 95.41 88.88
    RV + 1L 97.67 90.46 99.49 91.54 98.26 92.84
    FRC 98.85 97.53 98.34 94.41 97.85 90.85
    FRC + 1L 98.46 96.70 98.76 94.51 98.10 93.11
    TLC 99.46 95.58 99.12 93.14 97.82 97.50
Acquisition, Hscore
    RV 8.96 12.53 11.63 NA 10.16 16.16
    RV + 1L 10.26 12.08 8.82 11.74 9.04 11.89
    FRC 8.85 11.01 9.15 10.91 8.90 10.82
    FRC + 1L 9.33 10.83 8.61 10.62 8.59 10.98
    TLC 6.15 8.10 7.33 8.95 6.50 8.38

RV, residual volume; RV + 1L, residual volume plus 1 liter of gas mixture; FRC, functional residual capacity; FRC + 1L, functional residual capacity volume plus 1 liter of gas mixture; TLC, total lung capacity; V, volunteer; %VV, percent lung ventilated volume; Hscore, local heterogeneity score.