Skip to main content
. 2019 Feb 8;12(3):516. doi: 10.3390/ma12030516

Table 5.

Welding parameters used in welding simulations. cooling medium: free air in temperature 20°C, preheating temperature: 65°C.

Process EPUL (J/mm) v (mm/s) k Heat Source Model Parameters *
Laser 330 33.3 0.8 2.5/2.0/8.0
Hybrid (laser) 250 0.8 2.5/2.0/9.0
Hybrid (MAG) 230 0.8 9.0/7.0/3.0

EPUL—energy per unit length, v—welding speed, k—welding method efficiency factor; * heat source model parameters (in SYSWELD): for 3D conical model (laser)—top diameter of weld/bottom diameter of weld/penetration; for double-ellipsoidal model (MAG)—molten pool length/molten pool width/penetration.