Skip to main content
. 2019 Jan 26;19(3):522. doi: 10.3390/s19030522

Table 5.

Mean accuracies over varying number of electroencephalography (EEG) channels.

No. of Electrodes in Selected Configuration Possible Configurations Mean Accuracy Achieved
6 AF3 F4 T7 P7 F3 O1 64.49
AF3 F4 T7 P7 F3 P8 70.35
AF3 F4 T7 P7 O1 P8 66.86
7 AF3 F4 T7 P7 F3 O1 P8 65.01
8 AF3 F4 T7 P7 F3 O1 P8 F8 69.94
AF3 F4 T7 P7 F3 O1 P8 AF4 74.81
AF3 F4 T7 P7 F3 O1 P8 F7 71.67
9 AF3 F4 T7 P7 F3 O1 P8 F8 F7 74.45
AF3 F4 T7 P7 F3 O1 P8 F8 AF4 67.92
AF3 F4 T7 P7 F3 O1 P8 F7 AF4 71.15