Skip to main content
. 2019 Jan 29;19(3):553. doi: 10.3390/s19030553

Table 1.

Detection counts and true-positive rates from shots fired at increasing distances from the AudioMoth deployment location. These sites varied in terms a wide variety of variables including terrain, wind direction, and foliage thickness, resulting in an array of detection accuracies at distances greater than 500 m.

Distance from Source (m) 100 200 300 400 500 600 700 800 900 1000
Trial shots 12 22 34 34 49 18 31 21 13 18
Detected shots 12 22 33 29 23 5 14 0 9 1
TPR 1.00 1.00 1.00 0.94 0.54 0.25 0.48 0.00 0.67 0.08