Table 3.

Change of plate selection for complex distal tibia fracture after using 3D models.

Changed numbers (%) Not changed numbers (%) Total numbers
Inexperienced group 42 (74%) 15 (26%) 57
Experienced group 14 (31%) 31 (69%) 45

Inexperienced group: orthopedic surgeons who have operated less than 15 cases of distal tibia fracture.