Skip to main content
. 2019 Mar 4;14:9. doi: 10.1186/s13017-019-0229-2

Table 3.

Hemodynamic management without ICP monitoring during EES

Respondents (n = 122)
Safe SBP in patients at risk of IH during EES
 < 70 mmHg 1 (1%)
 70–80 mmHg 10 (8%)
 80–90 mmHg 20 (16%)
 90–100 mmHg 35 (29%)
 100–110 mmHg 35 (29%)
 > 110 mmHg 21 (17%)
Safe MAP in patients at risk of IH during EES
 > 60 mmHg 24 (20%)
 > 70 mmHg 44 (36%)
 > 80 mmHg 32 (26%)
 > 90 mmHg 22 (18%)

Abbreviations: SBP systolic blood pressure, MAP mean arterial pressure, EES emergency extracranial surgery