Figure 5.

Figure 5.

Recurrent incisional hernia after laparoscopic intraperitoneal onlay mesh repair (IPOM). (A) Coronal and (B) sagittal view of a 10 × 9 cm recurrent incisional hernia that was previously repaired with an open onlay mesh technique, followed by a laparoscopic IPOM repair. The current repair was performed with a bilateral transversus abdominis release and 28 × 30 cm mesh. Arrows and red line indicating defect and arrowhead in (A) showing previously placed mesh.