Skip to main content
. 2019 Mar 5;9:3543. doi: 10.1038/s41598-019-40010-0

Table 3.

Performance on digital clock drawing task variables in healthy control (HC) individuals, patients with amnestic mild cognitive impairment (aMCI) and patients with mild dementia due to AD (mAD).

Group p-value
HC aMCI mAD
n = 137 n = 138 n = 106
dCDT total time (ms) 43393.4 (15218.3) 69083.0 (32273.6) 105350.8 (61313.0) <0.0001
HC < MCI***
HC < mAD***
MCI < mAD***
dCDT time on surface (ms) 14550.9 (5069.5) 18641.4 (6660.3) 21027.8 (7277.5) <0.0001
HC < MCI***
HC < mAD***
MCI < mAD**
dCDT strokes per minute 39.4 (14.4) 32.7 (12.7) 24.6 (12.1) <0.0001
HC < MCI***
HC < mAD***
MCI < mAD***
dCDT time in air (ms) 13472.6 (4936.3) 24819.4 (13790.4) 38409.9 (24607.6) <0.0001
HC < MCI***
HC < mAD***
MCI < mAD***
dCDT time not painting (ms) 34264.4 (19458.7) 52519.8 (38932.7) 79341.5 (59763.3) <0.0001
HC < MCI***
HC < mAD***
MCI < mAD***
dCDT pen-up stroke length 2189.9 (10358.1) 3001.9 (1633.1) 3612.9 (2462.3) <0.0001
HC < MCI***
HC < mAD***
MCI < mAD*
dCDT pen-up/pen-down relation 1.07 (0.43) 1.32 (0.69) 1.63 (0.87) <0.0001
HC < MCI**
HC < mAD***
MCI < mAD**
dCDT velocity 9.4 (2.2) 8.3 (2.2) 7.0 (1.9) <0.0001
HC > MCI***
HC > mAD***
MCI > mAD***
dCDT pressure 0.31 (0.09) 0.29 (0.09) 0.33 (0.12) 0.033
dCDT pressure-velocity relation 2.18 (0.79) 2.21 (1.00) 2.82 (1.38) <0.0001
HC < mAD***
MCI < mAD***

*p < 0.05; **p < 0.001; ***p < 0.0001.

Values are displayed in mean (standard deviation); n = number; HC: healthy control individuals; aMCI: amnestic mild cognitive impairment; mAD: mild Alzheimer-type dementia; dCDT = digital Clock Drawing Test; ms = time in milliseconds.