Table 1.
Sensitivity and specificity of computed tomography carotid angiography based on North American Symptomatic Carotid Endarterectomy Trial criteria
| Stenosis (%) | CT type | Carotid arteries (n) | Sensitivity (%) | Specificity (%) | Reference |
| > 70 | Helical/spiral | 56 | 100 | 100 | Link et al12 |
| Dual source | 80 | 80 | 91 | Biermann et al13 | |
| Dual source | 80 | 100 | 84 | ||
| Axial | 44 | 67 | 96 | Leclerc et al14 | |
| Axial | 236 | 98.3 | 100 | Moll et al15 | |
| Helical/spiral | 44 | 100 | 100 | Randoux et al16 | |
| Helical/spiral | 59 | 65 | 100 | Patel et al17 | |
| Multi-detector | 129 | 90.9 | 54.9 | Bucek et al18 | |
| Multi-detector | 268 | 88.2 | 92.4 | Bartlett et al19 | |
| Helical/spiral | 73 | 75 | 96 | Silvennoin et al20 | |
| Axial | 45 | 90 | 87 | Howard et al21 | |
| Multi-detector | 336 | 95 | 99 | Anzidei et al22 | |
| Not known | 180 | 78 | 93 | Marquering et al23 | |
| Dual source | 80 | 80 | 100 | Tsiflikas et al24 | |
| Dual source | 80 | 91 | 83 | ||
| Axial | 48 | 81.8 | 100 | Gupta et al25 | |
| > 60 | Axial | 96 | 87 | 90 | Magarelli et al26 |
| Occlusion | Axial | 236 | 100 | 100 | Moll et al15 |
| > 50 | Multi-detector | 129 | 95.8 | 59.6 | Bucek et al18 |
| Multi-detector | 268 | 75 | 93.8 | Bartlett et al19 | |
| Helical/spiral | 73 | 88 | 82 | Silvennoin et al20 | |
| Not known | 180 | 75 | 98 | Marquering et al23 | |
| Axial | 48 | 91.7 | 72.7 | Gupta et al27 | |
| Axial | 72 | 85 | 83 | ||
| < 50 | Multi-detector | 268 | 95.2 | 93.2 | Bartlett et al19 |
CT, computed tomography.