Table 2.
Selection of reporter tools to quantify metabolites.
| Tool | Method | Description | Validated in zebrafish | Reference |
|---|---|---|---|---|
| Perceval | Fluorescent biosensor | Genetically encoded ratiometric fluorescent reporter for ATP/ADP ratios | No | Berg et al., 2009 |
| GCaMP6s | Fluorescent biosensor | Genetically encoded intensiometric fluorescent reporter for calcium | Yes | Chen J. et al., 2017; Singh et al., 2017; Janjuha et al., 2018a |
| RoGFP2-Orp1 | Fluorescent sensor | Genetically encoded ratiometric fluorescent reporter for H2O2 detection | Yes | Panieri et al., 2017 |
| Grx1-RoGFP2 | Fluorescent sensor | Genetically encoded ratiometric fluorescent reporter for GSH:GSSG redox potential | Yes | Panieri et al., 2017 |
| Cyto-roGFP | Fluorescent biosensor | Genetically encoded ratiometric fluorescent reporter for Redox state (Cytosol) | No | Waypa et al., 2010 |
| Matrix-roGFP | Fluorescent biosensor | Genetically encoded ratiometric fluorescent reporter for Redox state (Mitochondrial Matrix) | No | Waypa et al., 2010 |
| GPD-roGFP | Fluorescent biosensor | Genetically encoded ratiometric fluorescent reporter for Redox state (Mitochondrial Innermembrane space) | No | Waypa et al., 2010 |
| Pyronic | FRET biosensor | Genetically encoded ratiometric fluorescent reporter for pyruvate | No | San Martin et al., 2014 |
| Laconic | FRET biosensor | Genetically encoded ratiometric fluorescent reporter for lactate | No | San Martin et al., 2013 |
| pHRed | Fluorescent biosensor | Genetically encoded intensiometric fluorescent reporter for pH | No | Tantama et al., 2011 |
| Peredox-mCherry | FRET biosensor | Genetically encoded intensiometric fluorescent reporter for NADH/NAD ratio | No | Hung et al., 2011 |
| iNap1 | Fluorescent biosensor | Genetically encoded ratiometric fluorescent reporter for NADPH | Yes | Zou et al., 2018 |
| SoNar | Fluorescent biosensor | Genetically encoded fluorescent reporter for NADH | Yes | Zhao et al., 2016; Zou et al., 2018 |
| HyPerRed | Fluorescent biosensor | Genetically encoded intensiometric fluorescent reporter for H2O2 | Yes | Zou et al., 2018 |