Table 1.
An overview on some methods based on nanomaterials for the determination of H2O2. L—chemiluminescence; LOD—limit of detection.
| Materials Used | Method Applied | LOD (nmol·L−1) | Linear Range (µmol·L−1) | Stability | Reference |
|---|---|---|---|---|---|
| Hemin-functionalized WS2 nanostructures (NS) | Colorimetric | 1500 | 5–200 | - | [54] |
| Mb nanoporous ZnO films | Electrochemical | 2000 | 10–1800 | 2 weeks | [55] |
| WS2 NS and AgNC mixture | Stopped-flow CL | 0.6 | 0.0025–1.5 | 1 month | [56] |
| WS2 NS/AgNC nanocomposite | Fluorescence | 21 | 0.05–400 | 1 month | [57] |
| NiO nanoparticle (NP) modified with 5,10,15,20-tetrakis(4-carboxyl phenyl)-porphyrin | Colorimetric | 8000 | 20–100 | 2 h | [58] |
| WS2 quantum dots (QDs) | Stopped-flow CL | 2.4 | 0.004–1 | 1 month | This work |