Skip to main content
. 2019 Feb 26;2019:6481654. doi: 10.1155/2019/6481654

Table 2.

Comparison between flow cytometry (FCM) and automatic blood analyzer (ABA) for screening of fetal maternal hemorrhage (FMH) in puerperal women (n=40). Thresholds were specified for FCM and ABA following the assessment of blood samples of male adults added with fetal blood. Blood samples were prepared by serially diluting umbilical cord blood in blood of male adults at dilutions 1/10, 1/100, 1/1,000, and 1/10,000.

All dilutions 1:10 1:100 1:1.000 1:10.000
ABA ABA ABA ABA ABA
Threshold < 0.500 ≥ 0.500 Total Threshold < 2.500 ≥ 2.500 Total Threshold <0.500 ≥ 0.500 Total Threshold < 2.500 ≥ 2.500 Total Threshold < 0.500 ≥ 0.500 Total

FCM < 0,0945 27 11 38 < 3,020 32 8 40 < 0,450 29 11 40 < 0,096 30 8 38 < 0,061 22 11 33
≥ 0,0945 2 0 2 ≥ 3,020 0 0 0 ≥ 0,450 0 0 0 ≥ 0,096 2 0 2 ≥ 0,061 7 0 7
Total 29 11 40 Total 32 8 40 Total 29 11 40 Total 32 8 40 Total 29 11 40