Skip to main content
. Author manuscript; available in PMC: 2020 Feb 1.
Published in final edited form as: J Comput Neurosci. 2018 Sep 12;46(1):107–124. doi: 10.1007/s10827-018-0694-8

Table 4.

Comparison of AUROC, TP and FP statistics for change-point detection based on a single brain region. The TP and FP rates are computed using a significance threshold θ0 = 1.65 (i.e., P < 0.05).

AUROC TP FP
Session 1 2 3 4 1 2 3 4 1 2 3 4
Method
single
ensemble
0.79 0.78 0.97 0.93 77% 70% 100% 92% 33%  27%  24% 19%
0.85 0.91 0.98 0.94 77% 78% 100% 100% 13%  9%  24% 15%