Skip to main content
. 2018 Mar 15;10(3):322. doi: 10.3390/polym10030322

Table 1.

Operative injection molding conditions (Tmelt = melt temperature; Tmold = mold temperature; Pholding = holding pressure; Tlevel = temperature reached on the cavity surface thanks to the activation of the heating device).

Test Tmelt [°C] Tmold [°C] Pholding [MPa] Holding time [s] Tlevel [°C] Heating time [s]
CIM 220 28 26 2 28 0
80-07 220 28 26 2 80 0.7
120-07 220 28 26 2 120 0.7
160-07 220 28 26 2 160 0.7
80-18 220 28 26 2 80 18
120-18 220 28 26 2 120 18
140-18 220 28 26 2 140 18
160-18 220 28 26 2 160 18