Skip to main content
. 2018 May 7;10(5):509. doi: 10.3390/polym10050509

Table A1.

Tensile properties of biocomposite PHBHV90MIS10 (DCP) determined by tensile tests.

Sample E (Mpa) σmax (Mpa) εr (%)
PHBHV90MIS10 (DCP) 1099 ± 65 22 ± 2.0 7 ± 1.0