Figure 8.

Figure 8

Two-point focusing experiment. (a) The position of the two absorbers, where both absorbers are perpendicular to the laser incident direction and the axial direction of the ultrasonic transducer. (b) Comparison of three photoacoustic signals. The blue line represents the photoacoustic signal when the DMD loads a random mask, and the black line represents the photoacoustic signal when the DMD pixels are fully turned on. The red line represents the photoacoustic signal under the optimal mask after optimization. (c) The evolution curve of the averaged fitness value (in the two-point focusing experiment, the fitness value is the square root of the two photoacoustic signals’ product of peak to peak value) in the evolution process of the genetic algorithm. (d) The focusing image captured by the CCD after optimization.