Operational conditions in all enrichment SBRs from the experimental design.

Run Cycle Length
(h)
Acetate Concentration in the Feed (mM) Organic Loading Rate (g/L·d) SRT *
(d)
SBR #1 4 30 1.4 1.3
SBR #2 4 75 3.4 1.3
SBR #3 4 120 5.4 1.3
SBR #4 8 30 0.7 2.7
SBR #5 8 75 1.7 2.7
SBR #6 8 75 1.7 2.7
SBR #7 8 75 1.7 2.7
SBR #8 8 120 2.7 2.7
SBR #9 12 30 0.5 4.0
SBR #10 12 75 1.1 4.0
SBR #11 12 120 1.8 4.0

* Since no biomass retention was applied, SRT is equal to HRT.