Skip to main content
. 2019 Jan 24;11(2):207. doi: 10.3390/polym11020207

Table 2.

Tested results of LOI and cone calorimeter test (0–400 s).

Samples LOI (%) PHRR (kW/m2) av-EHC (MJ/kg) THR (MJ/m2) TSR (m2/m2) av-COY (kg/kg) av-CO2Y (kg/kg)
Neat RPUF 19.4 322 ± 8 20.8 ± 1.0 27.1 ± 0.8 899 ± 22 0.24 ± 0.04 2.52 ± 0.23
8ATH/14B/6E/PU 31.2 120 ± 2 18.5 ± 0.0 19.4 ± 0.3 625 ± 19 0.20 ± 0.02 2.20 ± 0.14
14ATH/14B/6E/PU 34.0 117 ± 2 18.8 ± 0.8 20.1 ± 0.1 496 ± 16 0.21 ± 0.05 2.31 ± 0.04
8AO/14B/6E/PU 30.6 129 ± 2 17.1 ± 0.7 21.7 ± 0.4 709 ± 17 0.21 ± 0.03 1.95 ± 0.30
14AO/14B/6E/PU 30.7 129 ± 2 17.3 ± 0.4 21.1 ± 0.7 707 ± 28 0.28 ± 0.00 2.48 ± 0.02
19.6B/8.4E/PU 31.0 132 ± 5 18.2 ± 0.4 20.9 ± 0.7 744 ± 21 0.22 ± 0.01 2.36 ± 0.01
28ATH/PU 22.3 285 ± 15 21.0 ± 0.1 35.5 ± 0.3 1165 ± 34 0.19 ± 0.03 2.32 ± 0.50
28AO/PU 24.5 215 ± 10 18.5 ± 0.8 32.4 ± 0.5 1091 ± 47 0.18 ± 0.01 2.64 ± 0.07