Results of non-combustion test and gross heat of combustion test in samples (1/1.5) with different PU waste.

Sample 1/1.5 (P) 1/1.5 (SG) 1/1.5 (A) 1/1.5 (B) 1/1.5 (I)
Temperature increase (°C) 71.15 * * 16.6 19.5
Flaming time (s) 339 * * NONE NONE
Loss of mass (%) 37.89 * * 26.63 27.72
Superior Calorific Power (MJ/kg) - - - 1.048 1.596