Skip to main content
. Author manuscript; available in PMC: 2020 Jan 1.
Published in final edited form as: Am Stat. 2018 May 10;73(1):43–49. doi: 10.1080/00031305.2017.1328375

Table 3.

Estimated power (%) of the WMW and FP tests. The FP test uses the variance estimator based on formula (2). X ~ Logistic(0,1), Y ~ Logistic(μy,sy). μy is set to 1, 1.2 and 0.8, respectively for the three sy at m = 30 and 2, 2.4 and 1.6, respectively for the three sy at m = 10 to achieve a comparable level of power.

sy n = m n = 2m n = 4m
WMW FP WMW FP WMW FP
normal approx., m = 30
1 57 59 71 72 79 79
2 38 38 49 57 58 75
0.5 60 59 71 64 77 67

permutation, m = 30
1 58 58 71 71 79 78
2 39 37 49 55 58 73
0.5 60 58 71 63 77 65

permutation, m = 10
1 64 66 80 79 87 84
2 43 44 59 64 70 80
0.5 66 66 79 72 85 73