Skip to main content
. 2019 Mar 18;9:4726. doi: 10.1038/s41598-019-41265-3

Table 2.

Vibrating sample magnetometer measurements.

LW-ONW LW-ONW (102.4 kA) LW-NINW LW-NINW (102.4 kA) OBS1 OBS1 (103.2 kA) ECF2LAP ECF2LAP (101.6 kA) R-1 R-1 (~25 kA) R-1 (7.0 kA) K38-PC2 K38-PC2 (23.4 kA) K38-PC2 (7.0 kA) SHV347-B SHV347-B (~25 kA) SHV347-B (7.2 kA)
Ms (A·m2/kg) 1.46 1.85 1.71 2.32 0.20 5.39 0.92 2.98 0.71 0.86 1.01 1.99 2.29 2.05 1.91 2.28 1.92
Mr (A·m2/kg) 0.39 0.34 0.57 0.49 0.02 0.09 0.15 0.16 0.13 0.13 0.12 0.30 0.27 0.30 0.34 0.32 0.32
Hc (kA/m) 26.58 22.36 45.68 33.18 6.37 4.38 13.53 9.71 15.68 14.16 12.97 9.87 7.32 9.63 13.45 11.86 12.65
R-1 R-1 (25.4 kA) R-1 (7.2 kA) K38-PC2 K38-PC2 (25.6 kA) K38-PC2 (6.9 kA) SHV347-B SHV347-B (24.9 kA) SHV347-B (7.0 kA)
Ms (A·m2/kg) 0.67 1.70 2.04 1.99 2.31 2.10 1.91 2.47 2.05
Mr (A·m2/kg) 0.12 0.13 0.15 0.30 0.30 0.29 0.34 0.35 0.30
Hc (kA/m) 15.28 9.71 6.45 10.27 8.28 9.71 13.29 11.86 10.58

Measurement of all samples in the upper half of the table, with pre-experimental values labeled with just the sample name and post-experimental values labeled with the sample name and the peak current value in parentheses; Repeated measurement of intermediate samples in the lower half of the table to check for pre-experimental consistency and post-experimental variability. Saturation magnetization (Ms), remanent magnetization (Mr), and coercivity (Hc) are shown.