Table 2.

Pooled sensitivity and specificity of TB-LAMP

Reference Standard Pooled Sensitivity Pooled Specificity
TB-LAMP accuracy if used as an alternative test for smear microscopy in all adults
 Standard 1a 77·7 (71·2–83·0) 98·1 (95·7–99·2)
 Standard 2a 76·0 (69·9–81·2) 98·0 (96·0–99·0)
 Standard 3a 80·3 (70·3–87·5) 97·7 (96·1–98·7)
TB-LAMP accuracy if used as an alternative test for smear microscopy in HIV-positive adults
 Standard 1a N/A (< 4 studies) N/A (< 4 studies)
 Standard 2a 63·8 (49·0–76.4) 98·8 (85·1–99·9)
 Standard 3a 73·4 (51·9–87·6) 95·0 (64·0–99·5)
TB-LAMP accuracy if used as an add-on test in smear-negative adults
 Standard 1a 42·1 (30·0–55·3) 98·4 (95·9–99·4)
 Standard 2a 42·2 (27·9–57·9) 98·0 (96·0–99·0)
 Standard 3a 40·3 (27·9–54·0) 97·7 (96·1–98·6)
TB-LAMP accuracy in studies comparing to Xpertb
 Standard 1a 78·0 (66·6–86·4) 98·9 (97·4–99·6)
 Standard 2a 74·1 (64·1–82·2) 98·8 (96·8–99·6)
 Standard 3a 75·8 (63·2–85·0) 98·2 (96·0–99·2)
Xpert accuracy in studies comparing to TB-LAMPb
 Standard 1a 81·1 (70·6–88·5) 98·2 (95·9–99·2)
 Standard 2a 80·4 (73·4–85·9) 97·4 (94·9–98·7)
 Standard 3a 84·0 (75·6–90·0) 97·2 (94·4–98·6)

aAll reference standards classify patients as having TB if ≥1 positive culture was confirmed as M. tuberculosis by speciation testing. To be classified as not having TB, patients were required to have no positive and at least 1) two negative cultures on two different sputum specimens (Standard 1); 2) two negative cultures on the same or different sputum specimens (Standard 2); or 3) at least one negative culture (Standard 3)

bData restricted to study participants who had valid results for both TB-LAMP and Xpert and testing performed on non-frozen specimens

Abbreviations: N/A not applicable