Table 3.

GTV and PTV 95% isodose line coverage.a

Patient number. Change in volume GTV coverage on original plan PTV coverage on original plan GTV coverage with target volume change (before plan adaptation) PTV coverage with target volume change (before plan adaptation) GTV coverage with target volume change (after plan adaptation) PTV coverage with target volume change (after plan adaptation) Treatment position offsets before plan adaptationb
1. Increase 99.86% 96.16% 91.7% 86.84% 99.78% 97.12% Not acceptable
2. Increase 100% 95.16% 93.2% 89.8% 100% 98% Acceptable
3. Decrease 99.76% 96.34% 100% 100% 99.41% 96.28% Not acceptable
4. Increase 99.62% 97.6% 92.9% 88.6% 99.86% 97.32% Acceptable
a

Target volumes coverage requirements followed ICRU 83 recommendations.

b

Changes in patient anatomy may result in positioning errors; sometimes setup offsets are tolerable, but in some cases cannot be corrected.