Skip to main content
. 2019 Mar 5;19(5):1112. doi: 10.3390/s19051112

Table 4.

The comparison between predicted and experimental depositions.

Band Temperature (°C) Humidity Speed (m·s−1) Height (m) Wind Speed (m·s−1) Predicted Deposition (μL·cm−2) Experimental Deposition (μL·cm−2) Deviation (%)
F1-2 20.65 72.9% 2.07 1.94 0.25 0.3058 0.317 3.66
F1-5 20.65 72.9% 2.26 2.13 0.23 1.1284 0.974 13.68
F1-8 20.65 72.8% 2.45 2.15 0.17 0.6291 0.613 2.56
F1-11 20.65 72.8% 2.89 2.21 0.21 1.5137 1.396 7.78
F1-14 20.65 72.8% 2.25 2.17 0.23 1.2231 1.258 2.85
F1-17 20.65 72.8% 2.31 2.05 0.19 0.6145 0.636 3.50
F1-20 20.65 72.8% 2.46 2.12 0.21 0.9473 0.886 6.47
F1-23 20.65 72.8% 2.43 2.14 0.20 1.5348 1.756 14.41
F2-2 21.91 68.6% 3.16 2.06 1.08 1.3961 1.265 9.39
F2-5 21.91 68.6% 3.25 2.27 0.98 1.6087 1.476 8.25
F2-8 21.91 68.6% 3.30 2.24 0.67 0.2973 0.324 8.98
F2-11 21.91 68.6% 3.35 2.35 0.84 0.6239 0.662 6.11
F2-14 21.91 68.6% 3.41 1.94 1.05 0.8953 0.876 2.16
F2-17 21.91 68.6% 3.75 1.68 1.14 0.3769 0.313 16.95
F2-20 21.91 68.6% 3.70 1.75 1.32 1.6481 1.849 12.19
F2-23 21.91 68.6% 3.59 1.45 1.09 1.5649 1.307 16.48