Skip to main content
. 2019 Mar 5;12(5):749. doi: 10.3390/ma12050749

Table 1.

Vickers hardness and fracture toughness of samples with optimal in-line transmittance.

Sample Content of Zirconia (wt%) Average Grain Size of HIPed Sample (μm) Pre-Sintering Temperature (°C) Vickers Hardness (GPa) Fracture Toughness (MPam)
A1 0 1.3 1500 14.47 ± 0.14 1.41 ± 0.04
B1 0.01 1.7 1500 14.23 ± 0.37 1.47 ± 0.04
C1 0.05 2.0 1500 14.18 ± 0.15 1.43 ± 0.04