Skip to main content
. Author manuscript; available in PMC: 2019 Mar 22.
Published in final edited form as: J Control Release. 2017 Jun 29;260:234–246. doi: 10.1016/j.jconrel.2017.05.034

Table 5.

Comparison of ML and B & M results for both scenarios: main barrier located in the lipid and main barrier located in the corneocytes.

Property Experimental values Main barrier: lipid Main barrier: corneocyte
ML B & M ML B & M
Caffeine
Dlip-lat cm2/s 2.71 × 10−8 2.71 × 10−8
Dcor cm2/s 5.58 × 10−6 1.28 × 10−11
Dlip-trans cm2/s 1 × 10−11
Cv μg/ml 19,465 19,465 19,465
Jss μg/cm2h 2.95 ± 1.5 5.87 5.88 0.22 0.75
kp cm/h 1.516 × 10−4 3 × 10−4 3 × 10−4 1.1 × 10−5 3.84 × 10−5
τ h 2.3 ± 1.5 15 15.1 57.27 16.73
Nicotine
Dlip-lat cm2/s 4.06 × 10−8 4.06 × 10−8
Dcor cm2/s 5.58 × 10−6 1.59 × 10−11
Dlip-trans cm2/s 3 × 10−11
Cv μg/ml 24,000 24,000 24,000
Jss μg/cm2h 130 ± 60 147.18 147.24 4.06 11.34
kp cm/h 5.42 × 10−3 6.13 × 10−3 6.13 × 10−3 1.7 × 10−4 4.73 × 10−4
τ h 1.6 ± 0.5 1.86 1.88 45.57 15.95
DEP
Dlip-lat cm2/s 2.01 × 10−8 2 × 10−8
Dcor cm2/s 4.72 × 10−6 1.09 × 10−11
Dlip-trans cm2/s 1 × 10−11
Cv μg/ml 1019.8 1019.8 1019.8
Jss μg/cm2h 21.0 ± 2.9 15.49 15.49 0.26 1.17
kp cm/h 2.06 × 10−2 1.52 × 10−2 1.52 × 10−2 2.6 × 10−4 1.15 × 10−3
τ h 0.66 ± 0.06 2.01 2.03 70.16 30.34