Skip to main content
. 2016 Apr 7;8(4):124. doi: 10.3390/polym8040124

Table 1.

Quasi-static tensile strength and stiffness of wide (left) and narrow (right) straps. The fibre parallel elastic modulus E11 [GPa] was calculated following [17] and was measured with strain gauges (E11_SG) and a linear encoder (E11_LE). The composite strains at failure εcf [%] were measured with the strain gauges. Wide straps are labelled with B, R or T, depending on the author who manufactured them, followed by the number of the strap. Narrow straps are labelled with BN and the number of the strap.

Strap σUTS [MPa] E11_SG [GPa] E11_LE [GPa] εcf [%] Strap σUTS [MPa] E11_SG [GPa] E11_LE [GPa] εcf [%]
Average 1,624 ± 121 177.8 ± 8.6 175.8 ± 12.1 0.99 ± 0.04 Average 1,714 ± 55 174.4 ± 1.1 166.2 ± 6.2 1.00 ± 0.05
B31 1,741 186.3 177.0 1.04 BN06 1,688 - 162.6 -
B32 1,538 187.7 180.3 0.95 BN09 1,663 - 158.7 -
B33 1,482 169.3 158.9 1.01 BN11 1,781 174.4 168.0 1.04
R56 1,611 174.3 - 1.00 BN15 1,767 173.4 166.4 1.02
R57 1,686 171.6 - 0.97 BN20 1,673 175.5 175.2 0.95
B01 1,637 - 187.2 -
B14 1,480 - - -
T72 1,815 - - -