Table 1.
Quasi-static tensile strength and stiffness of wide (left) and narrow (right) straps. The fibre parallel elastic modulus E11 [GPa] was calculated following [17] and was measured with strain gauges (E11_SG) and a linear encoder (E11_LE). The composite strains at failure εcf [%] were measured with the strain gauges. Wide straps are labelled with B, R or T, depending on the author who manufactured them, followed by the number of the strap. Narrow straps are labelled with BN and the number of the strap.
Strap | σUTS [MPa] | E11_SG [GPa] | E11_LE [GPa] | εcf [%] | Strap | σUTS [MPa] | E11_SG [GPa] | E11_LE [GPa] | εcf [%] |
---|---|---|---|---|---|---|---|---|---|
Average | 1,624 ± 121 | 177.8 ± 8.6 | 175.8 ± 12.1 | 0.99 ± 0.04 | Average | 1,714 ± 55 | 174.4 ± 1.1 | 166.2 ± 6.2 | 1.00 ± 0.05 |
B31 | 1,741 | 186.3 | 177.0 | 1.04 | BN06 | 1,688 | - | 162.6 | - |
B32 | 1,538 | 187.7 | 180.3 | 0.95 | BN09 | 1,663 | - | 158.7 | - |
B33 | 1,482 | 169.3 | 158.9 | 1.01 | BN11 | 1,781 | 174.4 | 168.0 | 1.04 |
R56 | 1,611 | 174.3 | - | 1.00 | BN15 | 1,767 | 173.4 | 166.4 | 1.02 |
R57 | 1,686 | 171.6 | - | 0.97 | BN20 | 1,673 | 175.5 | 175.2 | 0.95 |
B01 | 1,637 | - | 187.2 | - | |||||
B14 | 1,480 | - | - | - | |||||
T72 | 1,815 | - | - | - |