Table 3.
Results of DSC scans at 10 °C/min, for the neat epoxy resin and epoxy resins with 3 wt % of different carbon nanofillers: enthalpy changes, normalized with respect to the resin weight (∆HU), peak temperature (Tpeak), and fraction of catalyzed reaction.
Sample | ∆HU (J/g) | Tpeak °C | Amine catalyzed fraction (%) |
---|---|---|---|
Epoxy | 313.9 ± 1.1 | 113.7 ± 0.9 | 0 |
Epoxy + oCB-1 (O/C = 0.16) | 327.5 ± 2.2 | 96.5 ± 0.8 | 12 |
Epoxy + oCB-2 (O/C = 0.83) | 383.8 ± 1.1 | 96.2 ± 0.7 | 34 |
Epoxy + oCB-3 (O/C = 0.91) | 352.5 ± 1.7 | 88.7 ± 1.1 | 56 |
Epoxy + eGO (O/C = 0.62) | 374.4 ± 2.3 | 95.0 ± 0.7 | 29 |