Skip to main content
. 2017 Feb 12;9(2):51. doi: 10.3390/polym9020051

Table 2.

Amount of the primary antibody immobilization on the (PDDA/PAA)3.

Concentration of antibody (μg/mL) Primary IgG a (μg/cm2) IgG coverage b (%)
End-on Side-on
10 0.28 ± 0.01 15 104
20 0.42 ± 0.01 23 156
30 0.56 ± 0.03 30 207

a The dimension was calculated from the apparent area of filter (diameter was 13 mm). (n = 3); b The dimensions of the IgG are 14.5 nm × 8.5 nm × 4 nm [33]. When one assumes full monolayer coverage, the amount of IgG adsorption was 1.85 and 0.27 μg/cm2 in the end-on and side-on positions, respectively.