Skip to main content
. 2019 Apr 1;189:159–170. doi: 10.1016/j.neuroimage.2018.12.052

Table 2.

Optimal parameters for transverse orientation for different resolutions and when using parallel imaging. (I) in-plane resolution of 3 × 3 mm2, matrix size of 64 × 64 and slice thickness of 3 mm, (II) in-plane resolution of 2 × 2 mm2, matrix size of 96 × 96 and slice thickness of 2 mm and (III) parameters as in (II), using parallel imaging with GRAPPA, factor 2. As a measure of generalizability, the standard deviation for the BS-gain across subjects is listed.

Region of interest
Z-shim [mT/m*s]
Tilt [deg]
PE polarity
BS-gain [%]
Acquisition Protocol I II III I II III I II III I II III
mOFC + rACC −0.5 −1.0 −0.5 −45 −45 −45 Neg Neg Neg 37 ± 17 42 ± 20 37 ± 18
Inferior temporal lobes 0.0 0.5 0.5 45 45 45 Neg Neg Neg 12 ± 6 15 ± 9 19 ± 9
Temporal poles 1.0 1.5 1.0 45 45 45 Neg Neg Neg 44 ± 17 55 ± 21 51 ± 19
Amygdala 1.5 1.5 1.5 −45 −45 −45 Pos Pos Pos 44 ± 23 50 ± 25 47 ± 21
Hippocampus + Parahippocampus 0.5 0.5 0.5 45 45 45 Neg Neg Neg 30 ± 9 42 ± 13 39 ± 12